Available now
Thermal Performance – Cosytherm Rockwool
Cosytherm Rockwool Cavity Wall Insulation has a thermal conductivity of 0.039 W/mK.
Typical U-values (W/m2K) for masonry cavity walls insulated with Cosytherm Rockwool Cavity Wall Insulation
Cosytherm Rockwool Thickness (mm) |
Brick outer leaf/cavity/100mm block inner leaf type: |
||||
Dense block (λ=1.13) |
Medium block (λ=0.51) |
Lightweight Aggregate (λ=0.34) |
Standard Aircrete (λ=0.16) |
Lightweight Aircrete (λ=0.11) |
|
100 |
0.32 |
0.31 |
0.30 |
0.28 |
0.27 |
85 |
0.36 |
0.35 |
0.34 |
0.32 |
0.30 |
75 |
0.40 |
0.38 |
0.37 |
0.35 |
0.33 |
65 |
0.45 |
0.43 |
0.41 |
0.38 |
0.36 |
50 |
0.54 |
0.51 |
0.49 |
0.45 |
0.42 |
Notes: The U-values have been calculated assuming that all walls are lined with plasterboard on dabs. Block sizes assumed to be 440 x 215mm, mortar joints assumed to be 10mm wide, wall ties assumed to be stainless steel with a cross-sectional area of 12.50mm2. The U-values have been calculated to BS EN ISO 6946: 1997.
Thermal Performance – Cosytherm Whitewool
Cosytherm Whitewool Cavity Wall Insulation has a thermal conductivity of 0.040 W/mK.
Typical U-values (W/m2K) for masonry cavity walls insulated with Cosytherm Whitewool Cavity Wall Insulation
Cosytherm Whitewool Thickness (mm) |
Brick outer leaf/cavity/100mm block inner leaf type: |
||||
Dense block (λ=1.13) |
Medium block (λ=0.51) |
Lightweight Aggregate (λ=0.34) |
Standard Aircrete (λ=0.16) |
Lightweight Aircrete (λ=0.11) |
|
100 |
0.33 |
0.32 |
0.31 |
0.28 |
0.27 |
85 |
0.37 |
0.36 |
0.35 |
0.32 |
0.3 |
75 |
0.41 |
0.39 |
0.38 |
0.35 |
0.32 |
65 |
0.46 |
0.44 |
0.42 |
0.38 |
0.35 |
50 |
0.55 |
0.52 |
0.44 |
0.44 |
0.41 |
Notes: The U-values have been calculated assuming that all walls are lined with plasterboard on dabs. Block sizes assumed to be 440 x 215mm, mortar joints assumed to be 10mm wide, wall ties assumed to be stainless steel with a cross-sectional area of 12.50mm2. The U-values have been calculated to BS EN ISO 6946: 1997.